# DKS TCP/IP Server 11x17

*OCR extracted from DKS-TCP-IP-Server-11x17.pdf — 2 pages*

---

## Page 1

### WIRING FOR 1830-186 TCP/IP Server Mode to RS-232 CONVERTER KIT

**DKS DOORKING®**

---

#### Connection via INTERNET

**[Diagram - Left Side: Internet Connection Path]**

- Computer connected to cloud labeled **"Internet DKS Data over IP"**
- Cloud connects to **Network Interface Device** → **LAN** → **Modem** → **Router** (with ports labeled N.I.D. and 1, 2, 3, 4)
- **Ethernet wire runs limited to 330 Ft. Maximum.**
- Router connects via Ethernet (10M/100M) to **Network DC 5-18V** power supply → **RS-232 & 485 To Ethernet** converter (labeled **DKS DOORKING**)
- Converter has **RS-232** and **A(+) B(-) RS485** connections

**[Second Internet Connection Diagram - Lower Left]**

- Same path: Network Interface Device → LAN → Modem → Router
- Ethernet (10M/100M) → Network DC 5-18V → RS-232 & 485 To Ethernet converter (DKS DOORKING)
- Converter has **RS-232** and **A(+) B(-) RS485** connections

---

#### General Information

Use these instructions when using the TCP/IP adapter, part number 1830-186. This is a Plug and Play device (no manual setup required) and uses the DKS Data subscription service. For manual setup (no subscription required), use TCP/IP adapter part number 1830-185.

**NOTE: THIS DEVICE IS NOT COMPATIBLE WITH CELLULAR NETWORKS.**

You can use the 1830-186 Converter Kit with the following DKS Systems:
1833, 1834, 1835, 1837, 1838 with **REV Z** board (or higher).

16.5 VAC power is required at the Aux Terminal pins 1 and 2 in the 1830 Series controller:
Refer to these manuals for detailed 1830 Series wiring information:
- P/N 1834-065 or P/N 1835-065 Telephone Entry Systems Installation Manual
- P/N 1838-065 Access Controller Installation Manual

---

#### Connect Converter to 1830 Series Circuit Board RS-232 Terminals

**Note:**
RS-232 wire runs are limited to 500 feet maximum. If greater distance is needed, use RS232 to RS422 Extender Kit, P/N 1830-190 (4000 Feet maximum distance).

**RS-232 Pin Connection Table:**

| BOARD TERMINALS | DB - 9 PINS | DB - 25 PINS | FUNCTION |
|---|---|---|---|
| 1 | 3 | 2 | Transmit Data |
| 2 | 2 | 3 | Receive Data |
| 3 | 7 | 4 | Request to Send |
| 4 | 8 | 5 | Clear to Send |
| 5 | 5 | 7 | Signal Ground - Shell |
| 6 | | | Not Used |

**[Diagram - DB-9 Connector Pin Layout]**

- Pin 1: (top right)
- Pin 2: Black
- Pin 3: Red
- Pin 4: (unlabeled)
- Pin 5: Shield / Green
- Pin 6: (bottom)
- Pin 7: White
- Pin 8: Brown
- Pin 9: (bottom left)

**RS-232 Cable P/N 1818-040 (6 Ft. Cable)**

RS232 wire runs limited to 500 Ft. Maximum. See note above.

**Cable Wire Color to Pin Mapping:**

| Wire Color | Pin |
|---|---|
| RED | 1 |
| BLACK | 2 |
| WHITE | 3 |
| BROWN | 4 |
| GREEN | 5 |
| SHIELD | 6 |

**RS-232 wire terminal on telephone entry / access control system circuit board**

---

#### Connection via LAN

**[Diagram - Right Side: LAN Connection Path]**

- Computer connected to cloud labeled **"Internet DKS Data over IP"**
- Cloud connects to **Modem** → **Router** (with ports labeled N.I.D. and 1, 2, 3, 4)
- **Ethernet wire runs limited to 330 Ft. Maximum.**
- Router connects to **Network Interface Device** → **LAN**
- LAN connects via Ethernet (10M/100M) to **Network DC 5-18V** power supply → **RS-232 & 485 To Ethernet** converter (labeled **DKS DOORKING**)
- Converter has **RS-232** and **A(+) B(-) RS485** connections

**[Second LAN Connection Diagram - Lower Right]**

- Same LAN path with:
- Ethernet (10M/100M) → Network DC 5-18V → RS-232 & 485 To Ethernet converter (DKS DOORKING)
- Converter has **RS-232** and **A(+) B(-) RS485** connections

---

**P/N 1830-182 Rev J 5-24**

---

## Page 2

### Programming Instructions when using the 1830-186 Plug & Play TCP/IP Converter Kit

---

#### At the Programming Computer (PC Only)

**Step 1:** Install the Remote Account Manager software version 6.3 on the programming PC and register the software by following the on screen instructions.

> *[Screenshot: DKS Software registration/installation webpage]*

**Step 2:** Choose **IM / DKS VoIP** to register for a Data over IP or VoIP Voice + Data subscription.

> *[Screenshot: DKS Registration Manager webpage]*

**Step 3:** Complete the required contact information and then click Register.

> *[Screenshot: DKS Software registration form with contact fields]*

**Step 4:** Select the first choice.

> *[Screenshot: DKS registration options showing "Live Chat" and other choices]*

---

#### Setup the 1830 Series Entry System for Data over IP

**Step 1:** In Service Type, choose Data over IP.

**Step 2:** A 10 digit ID number will be generated for you.

**Step 3:** Enter the system Master Code.
(The Master Code can only be programmed at the entry system. Enter that Master Code here).

> *[Screenshot: Entry System Management dialog box showing fields for Service Type, system ID, and Master Code, with numbered indicators 1, 2, 3 pointing to respective fields]*

---

#### Setup an Account in the Remote Account Manager Software 6.3

**Step 1:** Connection Option, choose Data over IP.

**Step 2:** Enter the 10 digit ID number that was generated for you.

**Step 3:** Enter the system Master Code that was set at the entry system.

> *[Screenshot: Remote Account Manager Software 6.3 interface showing Station Plan(s) panel with fields for Connection Option, ID number, and Master Code, with numbered indicators 1, 2, 3]*

---

#### Program the 10-Digit Telephone Number / System ID at the Entry System

Program the 10 Digit ID Number at the entry system keypad:

1. \* 5 9 \_ \_ \_ \_ (Master Code) (beep).
2. Enter the 10 Digit ID Number: \_ \_ \_ \_ \_ \_ \_ \_ \_ \_ then press \* (beep).
3. Press 0 # together to exit the programming sequence (beeeeeep).

**To test the connection at the entry system:**

- \* 1 2 8 \_ \_ \_ \_ (Master Code). The system will respond with:
  - 1 beep – display reads "System is Registered" You're Done!
  - 2 beeps – display reads "Check Registration" Communication to the server is good, but check below for errors.

---

#### Summary

| | **Server Registration** | **System Information (software)** | **System (hardware)** |
|---|---|---|---|
| **1** | Service Type | Connection Option | |
| | *Must Match* | *Must Match* | |
| **2** | | | System ID |
| | *Must Match* | *Must Match* | *Must Match* |
| **3** | Master Code | Master Code | Master Code |
| | *Must Match* | *Must Match* | *Must Match* |